The process of compiling a Simulink model to run as a standalone application on a flash drive is described in detail in this Simulink documentation page. The procedure is summarized below, along with some workarounds required for our use-case to work with r2017b.
- Follow the procedure in Setting Up Development PC
- Create a bootable flash drive with FreeDOS using the Rufus tool (use the following settings)
- MBR partition scheme for BIOS or UEFI
- Add fixes for old BIOSes
- FAT32 file system
- 4096 bytes cluster size
- Create bootable disk using FreeDOS
- Copy the files in RealTimeModel to the FreeDOS USB drive. This replaces the AUTOEXEC.BAT file generated by Simulink Real-Time. It will never change from build to build, so make sure you never overwrite it with the generated AUTOEXEC.BAT file when you build a model.
- Select Stand Alone mode for the boot configuration in the Simulink Real-Time Explorer for the CassieV3 target (make sure to save the change)
- Make sure graphics mode is unchecked and USB support is checked under Target Settings
- Build the model that will be loaded onto Cassie (for example, model.slx)
- After the build completes, copy the following 3 files from the model_slrt_emb folder (listed below) to the flash drive (this folder can be found in the directory where the generated code is saved). DO NOT copy autoexec.bat.
- xpcboot.com
- slrtkrnl.rtb
- model.mldatx
- Set the target computer's BIOS settings to boot first from the flash drive (This has already been done by Agility, and is only required for setting up new targets)
- Plug the flash drive into the target computer USB port and power on
We have observed that Simulink Real-Time occasionally produces builds with an incorrect EtherCAT configuration, and one of the symptoms is that the battery status indicator on the radio displays a nonsense value (such as 231%). To avoid this, take the following steps before building a model:
- Clear the Cache and Code directories created by the Simulink Real-Time build processes
- Press ctrl-D on the Simulink model to update the diagram
- Start the build
We recommend using this procedure as a best practice to ensure a proper build.