Notifications
You must be signed in to change notification settings - Fork 0
/
Copy pathf_automation_node_instance_rep.py
99 lines (97 loc) · 9.39 KB
/
f_automation_node_instance_rep.py
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
from b_process_input_file import *
import re
import pdb
def create_automation_node_instance_rep(site):
'''Create Automation Node Instance Report'''
units_phases = process_units_phases()
units_phases["PhaseRep"] = units_phases["Phase"] + 'Report'
units_phases["UnitPhaseRep"] = units_phases["Unit"] + units_phases["PhaseRep"]
anir = ''
for UnitNumber, PhaseRep, UnitPhaseRep in zip(units_phases["Unit"].tolist(), units_phases["PhaseRep"].tolist(), units_phases["UnitPhaseRep"].tolist()):
unit_num_pattern = r'\d+'
# pdb.set_trace()
unit_no_prefix = int(re.findall(unit_num_pattern, UnitNumber)[0])
report_typicals = ["AddToRecLineReport", "DigestionReport", "DoseFTReport", "DoseReport",
"DrainDrumReport", "DrainFromMMReport", "DrainReport", "FlushReport",
"GasBaDoseFTReport", "GasBaDoseReport", "IFUReceiveReport", "MFUReceiveReport", "MixReport",
"PiggingReport", "PremixerDoseReport", "ReceiveByDSReport", "ReceiveByFTReport",
"ReceiveByWTReport", "ReceiveFromDrumReport", "ReceiveFromMMReport", "ReceiveParallelReport",
"RecycleReport", "RecycleSampleReport", "StopDoseFTReport", "StopDoseWTReport",
"TLUReceiveReport", "TransferToPackReport", "TrDrumReport", "WaitForAnalysisReport"]
if PhaseRep in report_typicals:
if "AddToRecLineReport" in PhaseRep: # Todo: Not configured in {site}, check Lote / ZJG / TLX
anir = anir + f'**Error** AddToRecLineReport Report not configured' + '\n'
if "DigestionReport" in PhaseRep:
anir = anir + f'"{UnitNumber}DigestionReport","DigestionTime","0","","{site}","NodeId","ns=1;s=t|{UnitNumber}DigestionTime","CyclicContinuous","Ti1s","None",""' + '\n'
if "DoseFTReport" in PhaseRep:
instrument_number = (unit_no_prefix * 10) + 8
anir = anir + f'"{UnitNumber}DoseFTReport","TankNetWeightDosed","0","","{site}","NodeId","ns=1;s=t|HFT_{instrument_number}_1TOT","CyclicContinuous","Ti1s","None",""' + '\n'
if "DoseReport" in PhaseRep: # Todo: Not configured in {site}, check Lote / ZJG / TLX
anir = anir + f'**Error** DoseReport not configured' + '\n'
if "DrainDrumReport" in PhaseRep: # Todo: Not configured in {site}, check Lote / ZJG / TLX
anir = anir + f'**Error** DrainDrumReport not configured' + '\n'
if "DrainFromMMReport" in PhaseRep:
anir = anir + f'"{UnitNumber}DrainFromMMReport","Drain-From-MM-Drain-Timer","0","","{site}","NodeId","ns=1;s=t|AlwaysZero","CyclicContinuous","Ti1s","None",""' + '\n'
anir = anir + f'"{UnitNumber}DrainFromMMReport","Drain-From-MM-Pause-Timer","0","","{site}","NodeId","ns=1;s=t|AlwaysZero","CyclicContinuous","Ti1s","None",""' + '\n'
anir = anir + f'"{UnitNumber}DrainFromMMReport","Drain-Weight-SP","0","","{site}","NodeId","ns=1;s=t|WT_{unit_no_prefix}3NET","CyclicContinuous","Ti1s","None",""' + '\n'
anir = anir + f'"{UnitNumber}DrainFromMMReport","Number-Of-Drain-Cycles","0","","{site}","NodeId","ns=1;s=t|AlwaysZero","CyclicContinuous","Ti1s","None",""' + '\n'
if "DrainReport" in PhaseRep:
anir = anir + f'"{UnitNumber}DrainReport","QuantityDrained","0","","{site}","NodeId","ns=1;s=t|WT_{unit_no_prefix}3NET","CyclicContinuous","Ti1s","None",""' + '\n'
if "FlushReport" in PhaseRep: # Todo: Not configured in {site}, check Lote / ZJG / TLX
anir = anir + f'**Error** FlushReport not configured' + '\n'
if "GasBaDoseFTReport" in PhaseRep: # Todo: Not configured in {site}, check Lote / ZJG / TLX
anir = anir + f'**Error** GasBaDoseFTReport not configured' + '\n'
if "GasBaDoseReport" in PhaseRep: # Todo: Not configured in {site}, check Lote / ZJG / TLX
anir = anir + f'**Error** GasBaDoseReport not configured' + '\n'
if "IFUReceiveReport" in PhaseRep: # Todo: Not configured in {site}, check Lote / ZJG / TLX
anir = anir + f'**Error** IFUReceiveReport not configured' + '\n'
if "MFUReceiveReport" in PhaseRep:
anir = anir + f'"{UnitNumber}MFUReceiveReport","NumberOfPackagedContainers","0","","{site}","NodeId","ns=1;s=t|AlwaysZero","CyclicContinuous","Ti1s","None",""' + '\n'
anir = anir + f'"{UnitNumber}MFUReceiveReport","NumberOfPackagedPallets","0","","{site}","NodeId","ns=1;s=t|AlwaysZero","CyclicContinuous","Ti1s","None",""' + '\n'
anir = anir + f'"{UnitNumber}MFUReceiveReport","PackagedQuantity","0","","{site}","NodeId","ns=1;s=t|{UnitNumber}PackagedQuantity","CyclicContinuous","Ti1s","None","" ' + '\n'
if "MixReport" in PhaseRep: ## remove this entry
anir = anir + f'**Error** MixReport not configured' + '\n'
if "PiggingReport" in PhaseRep: # Todo: Not configured in {site}, check Lote / ZJG / TLX
anir = anir + f'**Error** PiggingReport not configured' + '\n'
if "PremixerDoseReport" in PhaseRep:
instrument_number = (unit_no_prefix * 10) + 3
anir = anir + f'"{UnitNumber}PremixerDoseReport","TransferedQuantity","0","","{site}","NodeId","ns=1;s=t|WT_{instrument_number}NET","CyclicContinuous","Ti1s","None",""' + '\n'
if "ReceiveByDSReport" in PhaseRep: # Todo: Not configured in {site}, check Lote / ZJG / TLX
anir = anir + f'**Error** ReceiveByDSReport not configured' + '\n'
if "ReceiveByFTReport" in PhaseRep:
instrument_number = (unit_no_prefix * 10) + 3
anir = anir + f'"{UnitNumber}ReceiveByFTReport","RmDosedQuantity","0","","{site}","NodeId","ns=1;s=t|WT_{instrument_number}NET","CyclicContinuous","Ti1s","None",""' + '\n'
if "ReceiveByWTReport" in PhaseRep:
instrument_number = (unit_no_prefix * 10) + 3
anir = anir + f'"{UnitNumber}ReceiveByWTReport","RmDosedQuantity","0","","{site}","NodeId","ns=1;s=t|WT_{instrument_number}NET","CyclicContinuous","Ti1s","None",""' + '\n'
if "ReceiveFromDrumReport" in PhaseRep:
instrument_number = (unit_no_prefix * 10) + 3
anir = anir + f'"{UnitNumber}ReceiveFromDrumReport","RmDosedQuantity","0","","{site}","NodeId","ns=1;s=t|WT_{instrument_number}NET","CyclicContinuous","Ti1s","None",""' + '\n'
if "ReceiveFromMMReport" in PhaseRep:
instrument_number = (unit_no_prefix * 10) + 3
anir = anir + f'"{UnitNumber}ReceiveFromMMReport","RmDosedQuantity","0","","{site}","NodeId","ns=1;s=t|WT_{instrument_number}NET","CyclicContinuous","Ti1s","None",""' + '\n'
if "ReceiveParallelReport" in PhaseRep:
anir = anir + f'**Error** ReceiveParallelReport not configured' + '\n'
if "RecycleReport" in PhaseRep:
anir = anir + f'"{UnitNumber}RecycleReport","RecycledTime","0","","{site}","NodeId","ns=1;s=t|{UnitNumber}RecycleTimeCnt","CyclicContinuous","Ti1s","None",""' + '\n'
if "RecycleSampleReport" in PhaseRep:
anir = anir + f'"{UnitNumber}RecycleSampleReport","RecycledSmpTime","0","","{site}","NodeId","ns=1;s=t|{UnitNumber}RecycleSmpTimeCnt","CyclicContinuous","Ti1s","None",""' + '\n'
if "StopDoseFTReport" in PhaseRep: ## remove this entry
anir = anir + f'**Error** StopDoseFTReport not configured' + '\n'
if "StopDoseWTReport" in PhaseRep: ## remove this entry
anir = anir + f'**Error** StopDoseWTReport not configured' + '\n'
if "TLUReceiveReport" in PhaseRep:
anir = anir + f'"{UnitNumber}TLUReceiveReport","PackagedQuantity","0","","{site}","NodeId","ns=1;s=t|{UnitNumber}AmtLoaded","CyclicContinuous","Ti1s","None",""' + '\n'
anir = anir + f'"{UnitNumber}TLUReceiveReport","TruckCabin1Quantity","0","","{site}","NodeId","ns=1;s=t|AlwaysZeroReal","CyclicContinuous","Ti1s","None",""' + '\n'
anir = anir + f'"{UnitNumber}TLUReceiveReport","TruckCabin2Quantity","0","","{site}","NodeId","ns=1;s=t|AlwaysZeroReal","CyclicContinuous","Ti1s","None",""' + '\n'
anir = anir + f'"{UnitNumber}TLUReceiveReport","TruckCabin3Quantity","0","","{site}","NodeId","ns=1;s=t|AlwaysZeroReal","CyclicContinuous","Ti1s","None",""' + '\n'
anir = anir + f'"{UnitNumber}TLUReceiveReport","TruckCabin4Quantity","0","","{site}","NodeId","ns=1;s=t|AlwaysZeroReal","CyclicContinuous","Ti1s","None",""' + '\n'
if "TransferToPackReport" in PhaseRep:
anir = anir + f'**Error** TransferToPackReport not configured' + '\n'
if "TrDrumReport" in PhaseRep:
anir = anir + f'"{UnitNumber}TrDrumReport","WaitForDedrummingTime","0","","JUNDIAI","NodeId","ns=1;s=t|{UnitNumber}WaitForDedrumCnt","CyclicContinuous","Ti1s","None",""' + '\n'
if "WaitForAnalysisReport" in PhaseRep:
anir = anir + f'"{UnitNumber}WaitForAnalysisReport","AnalysisTime","0","","{site}","NodeId","ns=1;s=t|{UnitNumber}AnalysisTimeCnt","CyclicContinuous","Ti1s","None",""' + '\n'
else:
anir = anir + f'**Error** No matching phase name for {PhaseRep}. {UnitPhaseRep} automation node instance not created \n'
return anir